Data Centre Design/Life Cycle Overview
- Overview of the phases of a data centre life cycle
- Planning, re-alignment and continuous improvement
Standards and Rating Level Definitions
- Rating level of history
- Difference between Uptime and TIA-942 Rating level definitions
- Redundancy options (N+1), 2N, 2(N+1)
- Concurrent Maintainability/Compartmentalisation Example configurations
- Substation and feed requirements Maintenance options
- Operational processes guidelines/standards Skill development
Building Considerations
- Building location considerations
- Floor and hanging loads requirements
- Fire rating for walls and glass
- Blast protection Bulletproofing
- Forced entry protection
 Advanced Raised Floor & Suspended Ceiling
- Raised floor installation guidelines
- Techniques to install a proper and levelled raised access floor
- Common mistakes
- Choosing the right tiles and their locations
- Seismic-mitigating floor constructions
- Choosing the correct suspended ceiling
 Advanced Power
Power infrastructure layout;
- Formulas which you should know for the data centre
- Single Line Electrical diagrams; how to read to ensure key components are present for protection
- Overcurrent protection devices (MCB/MCCB/VCB/ACB/Fuses) definitions and what to use where
- Earth Leakage devices (RCB/RCD/ELCB/GFCI/ALCI/RCBO), definitions and what to use where
- Sizing of protective components
- Lightning strikes and surge protection devices (TVSS/SPD), how they operate, where to use and how to install
- Power cabling and cable run considerations
- PDU/DB setup and minimum requirements
Generators;
- Generator types: Standy/Prime/Continuous
- Component make-up and functions
- Fuel storage and calculation
- Paralleling of gen-sets
- Generator room/area requirements
UPS Systems;
- Required speci cations for UPS systems
- How to read data sheets and select the correct UPS
- Requirements for parallel configurations and avoid pitfalls such as single point of failures
- How parallel installation should be done, classic mistakes made by installers and how to avoid these
Harmonic Filters;
- Active/Passive filters and their application
Battery Banks;
- Battery bank terminology
- Designing battery banks, how to calculate, and double-check the battery bank to be installed
- Battery charging pitfalls and ensuring the right charger is being installed and used
- Using parallel battery banks; how to properly install them, limitations and risks when using batteries in parallel
- How to test batteries correctly and make decisions on cell/block or string replacement
- Battery casing choices; ABS, V0, V1, V2
- Alternative energy storage; wheel, re-usable cell, compressed air UPS, etc.
Advanced Electro-Magnetic Fields
- Sources of EMF
- Difference between single, three-phase and bus-bar EMF
- Options available to measure EMF and how to interpret the results from single-axis and composite measurements
- Guidance on safe distance for equipment and humans
- Calculation of EMF attenuation factor for shielding material permeability and saturation factors
Advanced Cooling
- Important definitions; dry-bulb, wet-bulb, dew-point, RH, sensible and latent heat
- Psychometric chart and ASHRAE recommendations
- Environmental class definitions and thermal specifications
- Temperature/humidity measurements guideline
- Heat dissipation methods
- Altitude impact on temperature intake to ICT equipment
- Floor plan set up for effective cooling
- Differences in tile surface and supporting structure and the air-ow performance impact
- Rack door construction and the flow performance impact
- Equipment Delta-T and its impact
- Optimising airflow
- Thermal units conversions
- Calculations for air volume displacement (CFM/CMH)
- Cooling capacity calculations
- Air-conditioning selection
- De - / humidifying options
- Air conditioning efficiency
- SHR impact on cost-saving
- Efficiency indicator
- New cooling principle and techniques (Submerged, VSD/VRF/ ECF/water- and air-side economisers)
- Redundancy guidelines for air- conditioners avoiding classic misconceptions and mistakes for meeting ANSI/TIA-942 compliant designs
- Installation requirements
- Connections to re panel and EPO
- Commissioning of air conditioners
- Setpoints and calibration
- CFD (Computational Fluid Dynamics)
Advanced Fire Protection
- The fire triangle and elements to stop a fire
- Detection systems in detail (VESDA, VIEW, smoke sensors)
- Considerations for installation of sensors
- Proper testing of smoke sensors
- Water-based systems i.e. deluge, wet-pipe, dry-pipe, pre-action and why most of them don’t work and how to detect this Details on Inert and Halocarbon systems and how to select the correct system for your data centre
- How to calculate the gas content ensuring the appropriate level is installed to suppress the fire including safety considerations
- Other requirements for gas systems such as release times, hold times, pipe install requirements and other important factors Requirements for the fire detection panel
- Installation verification, methods, what to check and how
- New advanced fire suppression technologies
Design and Install Scalable Networking Cabling System
- ANSI/TIA942 cabling structure topology ToR, EoR Design
- Intelligent patching systems
- Installation best practice such as routing, bending radius, separation from power, containment ll ratio, fibre link loss calculator, bonding and grounding requirement
- Standard for telecommunications labelling and administration
Environmental Speci cations and Contamination Control
- Acoustic noise effects, regulations, specifications and limits
- Data centre contaminations and classifications
- Measurements, standards and limits
- Preventive measures and avoidance
Data Centre Efficiency
- Business drivers to go Green
- High-availability or Green?
- Green guidelines and standards
- How to measure it and what are acceptable numbers compared to the general industry
- PUE classes defined by Green Grid and issues with PUE
- Techniques for saving energy in all parts of the data centre i.e. application/system level, cooling, power distribution
Mock Exam: CDCS - Certified Data Centre Professional